How to choose the appropriate
dust sampler
Vrins Luchtonderzoek has several dust samplers available, for rent and
for sale. A short description of the samplers is given on this website.
In the table below, the most important features of the samplers are shown.
The most important feature is the particle size fraction that is sampled.
Other features are typical time resolution, on-line or off-line, size
resolution (optical or aerodynamic) and typical stand-alone time for long-term
measuring campaigns.
|
Feature
|
Coarse
Dust
Recorder
|
Coarse
Dust
Monitor
|
Tunnel
Impactor
|
Aerosol
Tunnel
Sampler
|
High
Volume
Sampler
|
Osiris
|
Dust-
viewer
|
Microdust
|
| Size
fraction (µm) |
> 10
|
> 10
|
> 10
|
total dust
|
< 40
|
< 20
|
> 10
|
< 10
|
| Time
resolution |
1 hr
|
1 hr
|
10 min
|
1 hr
|
24 hr
|
1 sec
|
10 min
|
10 sec
|
| On-line |
-
|
+
|
-
|
-
|
-
|
+
|
+/-
|
+
|
Optical
size resolution
|
+
|
+
|
+
|
-
|
-
|
+/-
|
+
|
-
|
Aerodynamic
size resolution
|
-
|
-
|
+
|
-
|
-
|
-
|
-
|
-
|
| Stand-alone
time |
1 month
|
1 month
|
-
|
-
|
1 day
|
1 month
|
-
|
-
|
|